Misoprostol Prior to Intrauterine Contraceptive Device Insertion

Overview

Intrauterine devices (IUDs) are widely used as reversible contraceptives. Both copper- and levonorgestrel (LNG)-releasing IUDs (LNG-IUDs) are safe,cost-effective in the long term and equally effective compared with tubal sterilization. In addition, the LNG-IUD (Mirena®) provides non contraceptive benefits, such as treatment for menorrhagia, dysmenorrhea and anemia. The current use of IUDs among reproductive-aged women ranges from 8 to 15% worldwide. Reported complications related to IUD insertion are 8.8% insertion failure, 2.8-11.5% cervical problems, 0.2% cervical perforation, 0.2% syncope and 5.8% expulsion. Insertion failures and cervical problems seem to occur more often among women who have never delivered vaginally. Cervical stenosis, an immature or small cervix and a significantly ante- or retroverted position of the uterus, has been described as factors associated with a difficult sounding of the cervical canal or even failure to insert the IUD. Misoprostol is an inexpensive prostaglandin E1-analogue, which is associated with few side effect. More over several have shown the benefit of misoprostol as a cervical ripening agent in non pregnant women. Priming with misoprostol prior to hysteroscopy and dilatation and curettage (D&C) in perimenopausal women resulted in increased cervical dilatation and lower rate of cervical laceration. The effect of misoprostol on the cellular matrix causes dissolution of collagen fiber increasing the amount of fluid in the stroma and consequentially causes cervical effacement. Fear of pain during insertion, however, might prevent some women from choosing IUD and fears of painful and/or difficult placements may lead them to recommend or counsel women on other, less effective methods. Women's perception of pain is multifactorial and likely to be influenced by cultural differences and personal experiences; insertion-related pain is therefore difficult to predict. Nevertheless, factors associated with greater pain include nulliparity, not currently breastfeeding and longer time since last pregnancy; of these factors, nulliparity is the strongest predictor of pain. The proportion of women of reproductive age who are nulliparous is increasing, with women delaying childbirth and having fewer children or choosing to remain childless. The proportion of Caesarean section births has also increased and women who have only ever had a Caesarean section are often viewed as nulliparous with respect to IUD placement. Anticipated pain is often greater than the actual pain experienced, and the majority of nulliparous women experience no more than moderate pain during IUD insertion. However, among nulliparous women there is a subset (about 17%) for whom the insertion of IUD is associated with severe pain.These women need effective pain relief. For most nulliparous, nulligravid or parous women, IUD insertion can be performed successfully without cervical priming and with a minimum amount of discomfort. Whether selective use of misoprostol has a role in management of pain in certain subsets of women (e.g. nulliparous women and those in whom the insertion is non-routine/difficult) has yet to be adequately studied.

Full Title of Study: “Vaginal Misoprostol Prior to Intrauterine Contraceptive Device Insertion in Women With Previous Caesarean Section”

Study Type

  • Study Type: Interventional
  • Study Design
    • Allocation: Randomized
    • Intervention Model: Parallel Assignment
    • Primary Purpose: Prevention
    • Masking: Double (Participant, Investigator)
  • Study Primary Completion Date: April 2016

Interventions

  • Drug: Misoprostol
    • 400 µg misoprostol vaginally 3 hours before IUD insertion.
  • Drug: Placebo
    • This group will receive placebo

Arms, Groups and Cohorts

  • Active Comparator: Misoprostol group
    • Going to receive 400 µg misoprostol vaginally 3 hours before IUD insertion.
  • Placebo Comparator: Placebo group
    • Going to receive placebo.

Clinical Trial Outcome Measures

Primary Measures

  • easiness score of IUD insertion
    • Time Frame: 5 minutes

Secondary Measures

  • the difference in the pain intensity scores between the study groups
    • Time Frame: 5 minutes
  • the women’s level of satisfaction at the end of insertion
    • Time Frame: 5 minutes

Participating in This Clinical Trial

Inclusion Criteria

1. Include those who delivered by CS . 2. Who accept to participate in the study. 3. Desire IUD placement. 4. Negative pregnancy test. 5. No history or current history of pelvic inflammatory disease. 6. No current cervicitis. 7. No contraindication to IUD insertion (less than 4 week post partum,gynecological malignancy,unexplained vaginal bleeding and pregnancy). Exclusion Criteria:

1. Any contraindication to IUD . 2. Current pregnancy. 3. Uterine anomaly. 4. Undiagnosed abnormal uterine bleeding. 5. Allergy to misoprostol. 6. Patients contraindicated to administration of misoprostol. 7. Women who delivered vaginally.

Gender Eligibility: Female

Minimum Age: 18 Years

Maximum Age: 45 Years

Are Healthy Volunteers Accepted: No

Investigator Details

  • Lead Sponsor
    • Assiut University
  • Provider of Information About this Clinical Study
    • Principal Investigator: mohamad sayed abdellah, Dr – Assiut University

Clinical trials entries are delivered from the US National Institutes of Health and are not reviewed separately by this site. Please see the identifier information above for retrieving further details from the government database.

At TrialBulletin.com, we keep tabs on over 200,000 clinical trials in the US and abroad, using medical data supplied directly by the US National Institutes of Health. Please see the About and Contact page for details.