11C Methionine PET for the Detection of Hyperfunctional Parathyroid Tissues

Overview

The overall sensitivity and specificity of 11C-MET PET/CT is superior to 18F-FDG PET/CT and conventional SPECT-CT for the detection of abnormal parathyroid glands.

Full Title of Study: “Pre-operative Parathyroid Imaging: a Comparison of 11C-Methionine PET, 18F-FDG PET AND SPEC-CT for the Detection of Hyperfunctional Parathyroid Tissues”

Study Type

  • Study Type: Interventional
  • Study Design
    • Allocation: Non-Randomized
    • Intervention Model: Single Group Assignment
    • Primary Purpose: Diagnostic
    • Masking: None (Open Label)
  • Study Primary Completion Date: March 2018

Detailed Description

STUDY OBJECTIVES Primary: To compare the accuracy, sensitivity and specificity of 11C-methionine (MET) PET/CT and 99mTc-MIBI SPECT-CT in the detection of pathologic parathyroid glands in patients with primary hyperparathyroidism.

Secondary:To compare the accuracy, sensitivity and specificity of 11C-MET and 18F-FDG PET/CT scans in the detection of pathologic parathyroid glands in patients with primary hyperparathyroidism.

STUDY DESIGN A phase II diagnostic imaging, single-centre study to compare the accuracy of 11C-MET PET/CT with standard 99mTc-MIBI SPECT-CT and with 18F-FDG PET/CT imaging in patients with primary hyperparathyroidism.

STUDY POPULATION Number of Subjects: 50 patients Number of groups: 1: 50 with primary hyperparathyroidism. Age/Gender: Age greater than or equal to 19 years / Male and Female Study specific requirements: Subjects with clinically suspected primary hyperparathyroidism who require 99mTc-MIBI SPECT-CT parathyroid imaging.

INVESTIGATIONAL PRODUCT Product: 11C-Methionine Route of administration: Intravenous Dosage(s) and frequency: Radioactive dose of 11C-Methionine of 6 MBq per kilogram body weight per injection (maximum dose of 555 MBq); one injection per patient.

COMPARATOR PRODUCTS Product: 99mTc-Methoxyisobutylisonitrite; 18F-Fluorodeoxyglucose Route of administration: Intravenous Dosage(s) and frequency: (1) Radioactive dose of 99mTc-Methoxyisobutylisonitrite of 555 – 740 MBq per injection; one injection per patient. (2) Radioactive dose of 18F-Fluorodeoxyglucose of 296 – 521 MBq per injection; one injection per patient.

EVALUATION CRITERIA Efficacy: The comparison of the accuracy, sensitivity, and specificity of 11C-MET PET/CT with 99mTc-MIBI SPECT-CT and 18F-FDG PET/CT in the detection of pathologic parathyroid glands in patients with primary hyperparathyroidism.

Safety: Vital signs before and following 11C-MET administration; adverse events collection.

Interventions

  • Radiation: 11C-Methionine PET/CT scanning
    • PET with the radiopharmaceutical carbon-11 methionine (11C-MET) has been considered to improve diagnosis due to a superior spatial resolution and higher specificity compared to other radiotracers such as 18F-FDG. For the 11C-MET PET/CT, the patient will receive an intravenous bolus injection of 11C-MET as manufactured at the BCCA production facility at a dose of 6 (0.16 mCi) MBq per kilogram but not to exceed 555 MBq (15 mCi).
  • Radiation: 18F-FDG PET/CT scanning
    • For PET/CT scans, the patient will first receive an intravenous bolus injection of 18F-FDG as manufactured at the BCCA production facility in a dose determined by body weight but not to exceed 521 MBq (14.1 mCi). Our standard adult prescription (70kg adult) for 18F-FDG is 296 MBq (8.0 mCi). The target dose for body scans is increased by 59.2 MBq (1.6 mCi) for every 20 kg increase in body weight to a maximum target dose of 474 MBq (12.8 mCi).
  • Radiation: SPECT-CT scanning
    • For the SPECT-CT scan, each injection of intravenous 99mTc-MIBI is dosed at a maximum of 20 mCi (740MBq), as per usual standard of care. The energy window of each scan is at 140 keV, consistent with the standard of SPEC-CT imaging techniques.

Arms, Groups and Cohorts

  • Experimental: Primary hyperparathyroidism
    • Subjects with biochemical evidence, including elevated serum calcium and PTH levels, of primary hyperparathyroidism. All patients will undergo 11C-methionine PET/CT, SPECT-CT and 18F-FDG PET/CT scanning.

Clinical Trial Outcome Measures

Primary Measures

  • To compare the sensitivity of 11C-MET PET/CT, SPECT-CT and 18F-FDG PET/CT in the detection of pathologic parathyroid glands in patients with primary hyperparathyroidism
    • Time Frame: Patient will undergo the scans at baseline
    • Sensitivity is the percentage of patients that were correctly identified to have an abnormal parathyroid gland by the imaging studies.
  • To compare the specificity of11C-MET PET/CT, SPECT-CT and 18F-FDG PET/CT in the detection of pathologic parathyroid glands in patients with primary hyperparathyroidism
    • Time Frame: Patient will undergo the scans at baseline
    • Specificity is defined as the percentage of patients that were correctly rejected for having an abnormal parathyroid gland by the imaging studies.

Secondary Measures

  • To evaluate the safety profile of 11C-MET PET/CT.
    • Time Frame: Up to 2 weeks
    • All adverse events will be recorded. An Adverse Event (AE) is any untoward, undesired, unplanned medical occurrence in a participant and does not necessarily have a causal relationship with the study intervention. Expected adverse events from PET/CT scans include bruising, bleeding or infection at the site of intravenous radiotracer injection. Other expected adverse events include feeling of discomfort or claustrophobia from being in the scanner.

Participating in This Clinical Trial

Inclusion Criteria

  • Adults > age 18;
  • Able to provide written informed consent;
  • Subjects with biochemical evidence, including elevated serum calcium and PTH levels, of primary hyperparathyroidism.

Exclusion Criteria

  • Subjects with previous successful parathyroidectomy and parathyroid tissue reimplantation;
  • Pregnancy;
  • Subjects who are unable to tolerate the physical/logistical requirements of completing two PET/CT scans, including lying still for a prolonged period of time and receiving two intravenous injections.
  • Subjects who exceed the safe weight limit of the PET/CT bed (204.5 kg) or who cannot fit through the PET/CT machine (diameter 70cm).

Gender Eligibility: All

Minimum Age: 18 Years

Maximum Age: N/A

Are Healthy Volunteers Accepted: No

Investigator Details

  • Lead Sponsor
    • University of British Columbia
  • Collaborator
    • British Columbia Cancer Agency
  • Provider of Information About this Clinical Study
    • Sponsor
  • Overall Official(s)
    • Donald W Anderson, MD, FRCSC, Principal Investigator, University of British Columbia; Vancouver General Hospital
    • Don Wilson, MD, FRCPC, Principal Investigator, British Columbia Cancer Agency
  • Overall Contact(s)
    • Hayley Corbett, 604-877-6000, hayley.corbett@bccancer.bc.ca

Clinical trials entries are delivered from the US National Institutes of Health and are not reviewed separately by this site. Please see the identifier information above for retrieving further details from the government database.